LFC-N SERIES
Description
LFC-N cooling tower takes advantage of the water pressure of circulation pump forming the water screen with special ejection pipe nozzles. The pressure differential inside and outside the tower is generated by the flowing speed of water screen, thus causing the inhale of ambient cold air into the tower. The effectiveness of cooling down the water is achieved through the precise diffusers that can regulate the ambient air sucked in through the filling. Hence, the circulation water is fully in contact with the ambient air during water ejection and falling processes, resulting in rejected heat.
The ambient air of fanless cooling tower naturally enters the cooling tower due to the pressure differential caused by ejection water screen, thus there are no mechanical fan drive and transmission equipments. This breakthrough, creative, and revolutionary design can, once and for all, eliminate the problems of mechanical noises, vibration, and maintenance brought by fanned cooling towers. This is the best choice for the pursuits of safety, efficiency, and environmental concerns.
Super Low Noise
The noise of traditional cooling tower is generated by operating fan and motors. The body vibration induced by transmission equipment reinforces the noise resonance and can be effectively reduced by installing vibration isolators and channel base. The LFC-N cooling towers are fanless due to its unique cooling method, hence there are no troublesome noises and vibrations.
Water Saving and Pollution Free
LFC-N fanless technology tower applies transferring device of high efficient fluid dynamic energy to substitute fan motors. Although increased pump heads are required due to design requirements, the average total power consumption is equivalent between fanless and traditional fanned tower.
The air exhaust is designed with non-reducing ventilation so that the outlet air velocity is less than that of fan driven one by more than 60%. With the use of five-pass drift eliminators, depending on the ejection pressure, the drift loss can be controlled between 0.001% and 0.009%. Such drift loss is far lower than traditional fanned towers, hence a large volume of water can be conserved. The water drop is smaller than 50 μ and will evaporate immediately without any further pollution.
Low Maintenance Cost
LFC-N tower has no mechanical equipments of motor, speed reducer and transmission parts (ie, whole tower consist of non-moving parts). Under standard water quality conditions, as long as the circulation water is clean, there will be no trouble of unexpected shut-down and operation maintenance.
Standardized Modular Structure
All models are designed with modular structure. The components are produced with molds so that the stable performance is insured and can provide flexible arrangement to meet site space restrictions of the end user. Also, LFC-N cooling towers can be easily assembled and dismantled for future capacity expansion.
Safety, Grace and Compliance with Environmental
Protection
The LFC-N tower body is sturdy and firm, and has no electrical wiring disturbance, so that the tower can be randomly positioned without safety concerns. Low vibration noise, dust proof, low drift loss and recyclable components meets the demands of environmental protection in the 21st Century.